SATURN-15 GALVO

Description
The Saturn 15B optical scanner is specifically designed to meet the demands of applications having apertures in the 10mm to 15mm range, such as laser marking, laser welding, via-hole drilling, SLS 3D printing and large-beam laser displays. Several coil configurations are available including one with very low inductance and low coil resistance optimized for the fastest step-times, and another with moderate resistance and inductance optimized for large-signal applications such as laser displays.
Features of the Saturn 15b Galvanometer
- The Saturn 15B has nearly the same dimensions as a Cambridge model 6230 but around half the weight, so it may serve as a drop-in replacement that also offers a significant performance upgrade, particularly in applications that are sensitive to electrical power consumption and heat generation.
- The Saturn 15B has a rotor inertia of 0.54 Gm•Cm2, which is an inertia presently not served by other galvos on the market today. This rotor inertia allows more of the motor’s torque to be transmitted to the mirror and less to be expended moving the rotor itself. This rotor inertia, coupled with our highly efficient and patented X3 magnetic design, allows this scanner to do the same job as conventional galvos, while generating around 1/3 of the heat.
- Our patented position sensor design allows for wide-angle scanning up to 110 degrees optical with high output and low noise.
Specifications
Optimal Mirror Size: | 10mm |
Rotation Angle (1): | +\- 27.5 Degrees |
Rotor Inertia: | 0.54 Gram*Centimeter2 |
Torque Constant: | 110,000 Dyne*Centimeters per Ampere |
Maximum Coil Temperature: | 110 degrees Celsius |
Operating Temperature Range (2): | -10 to +85 Degrees Celsius, non-condensing |
Thermal Resistance, Coil to Mount: | 0.8 degrees Celsius per Watt, Maximum |
Coil Resistance: | 0.98 Ohms |
Coil Inductance: | 200 μh |
Back EMF Voltage (1): | 192 μV per degree per second |
Peak Current: | 25 Amperes, Maximum |
RMS Current: | 7.1 Amperes at Tcase of 50°C |
Power Handling Capacity: | 64 Watts at Tmount of 50°C |
Small Angle Step Response: | 260 μS with ScannerMAX 3mm mirror set |
PD Linearity over 20 degrees p-p(1): | 99.9 % Minimum |
PD Linearity over 40 degrees p-p(1): | 99.5 % Typical |
PD Output Signal (Common Mode)(1): | 640 μA (at 20mA LED current) |
PD Output Signal (Differential Mode)(1): | 43.6 μA perdegree (at 20mA LED current) |
Mass: | 140 Grams |
NOTE
- Angular specifications are in mechanical degrees. (110 degrees optical)
- Several factors impact the operating temperature range. Please contact us before operating at or outside the extremes.
Specifications are at a temperature of 25° C. All mechanical and electrical specifications are +/-10%. ScannerMAX scanners can easily be fabricated with alternative configurations. Please contact us with your requirements.